Features
- Charge for free: use PV surplus efficiently
- Electricity exchange included: charge cheaply even without a PV system – ideal for variable electricity tariffs
- Easy operation with the Touch Pure Flex or the Loxone app
- Fleet-ready: protection of the cable and the building thanks to optimal power distribution
- User identification and billing via NFC
- Up to 5 customisable charging modes
- Easy integration via Loxone Air – up to 3 additional Tree devices can be connected directly
- OCPP-capable
- MID compliance achievable in combination with the Loxone Energy Meter Tree
- Certified for TOR according to OVE R37:2024
Note
Via the integrated Tree interface you connect up to 3 Tree devices such as energy meters, NFC Code Touch or Touch devices directly.
Electrical specifications
| Rated voltage | AC input (mains voltage): 3x 230/400V or 1x 230V, 50-60Hz 24V DC output: 24V DC |
|---|---|
| Rated current | AC input (mains voltage): 3x 16A or 1x 16A 24V DC output: max. 100mA |
| Power consumption | AC input (mains voltage): Standby: 0.6W, Charging: 4W 24V DC output: – A 30 mA Type A residual current device (RCD) must be installed upstream of every wallbox. |
| Max. charging power | 11kW (3-phase 16A) 3.7kW (1-phase 16A) adjustable from 1.38kW to 3.7/11kW |
| Charging mode | Charging mode 3 (IEC 61851-1) |
| Residual current detection | Internal, RDC-MD, DC 6mA (IEC 62955) |
| Charging cable with plug | Type 2 plug (IEC 62196) 5 metre cable, 5×2.5mm² + 1×0.5mm² |
Interfaces
| LOXONE Air | Connection to Miniserver / Air Base Extension 868MHz (SRD band Europe), 4 channels, max. 15.1mWe.r.p. 915MHz (ISM band Region 2), 10 channels, max. 13.2mW Internal antenna |
|---|---|
| LOXONE Tree | Connection: up to 3 Tree devices Energymeter, Touch devices (e.g. Touch, Touch Pure Flex, NFC Code Touch) A connection to the Tree to Air Bridge is not supported. All other Tree devices are not officially supported, but can be connected at your own risk. Cable length: Tree devices must be installed directly inside the wallbox housing. Routing the Tree cables outside the wallbox is not recommended. |
| Modbus RTU for connecting energy meters | max. 1 device max. 3m cable length adjustable baud rate & parity data types: 16 & 32 bit min. polling cycle: 5s |
| OCPP | 1.6 & 2.0.1, NFC Code Touch required |
Ambient conditions
| Temperature | -20 … 50 °C / -4 … 122 °F |
|---|---|
| Humidity | max. 95 % RH (non-condensing) |
| Degree of protection | IP44 (IEC 60529) |
| Impact resistance rating | IK08 (IEC 62262) |
| Protection class | Class I |
| Installation | Stationary, surface mounting, vertical on a wall or charging post |
| Recommended mounting height | Cable outlet: 132cm / 52″ Top edge: 165cm / 65″ |
| Operating altitude | max. 2000 m |
Terminals
| Terminal type | AC input, charging output: DG2206V DC output: DG220B Modbus: SPTAF 1 |
|---|---|
| Conductor cross-section | AC input, charging output: 0.5 … 6mm² / AWG 20 … 8 DC output: 0.28 … 0.8mm² / AWG 23 … 18 Modbus: 0.25 … 0.75mm² / AWG 24 … 16 |
| Stripping length | AC input, charging output: 12mm / 0.47" DC output: 5 … 6mm / 0.2 … 0.24" Modbus: 8mm / 0.31" |
| Temperature resistance | AC input, charging output: -40 … 105°C / -40 … 221°F DC output: -40 … 105°C / -40 … 221°F Modbus: -60 … 100°C / -76 … 212°F |
| Connection compartment | DIN rail with 158mm / 6.2" width, space for devices with up to 9 pitch units |
Wiring diagram

Product properties
| Colour | Housing: RAL 9005 Decorative cover: RAL 9003 |
|---|---|
| Gloss level | Matt |
Weight & dimensions
| Net weight | 3.5 kg |
|---|---|
| Gross weight | 4.8 kg |
| Product dimensions | 430x190x130mm / 16.93×7.48×5.12" (HxWxD) |
| Package dimensions | 575x330x155mm / 22.64×12.99×6.1" (HxWxD) |
Product dimension drawing

Certifications & standards
| Pollution degree | 3 |
|---|---|
| Standards | CE (LVD 2014/35/EU, EMCD 2014/30/EU) IEC 61851-1 IEC 61851-22 |
| Certifications | Compatible with ChargePoint be.ENERGISED (OCPP 1.6) OVE R37:2024 (AT TOR) |