Touch Slim Flex 24V CO2 Air: slim and connected wirelessly
The Touch Slim Flex is the slim format of the Touch Flex: you define and combine up to 4 individual buttons or button pairs yourself in the Loxone Configurator. Data is transmitted wirelessly via Loxone Air; it is supplied with 24 V (10 … 30 V DC). As the wireless base, you need a Miniserver with Loxone Air or an Air Base Extension. It also measures the CO2 content of the room air (400 … 5,000 ppm). It fits US single-gang and Italian IT-503 flush-mounted boxes.
With CO2 sensor and Tree cabling, there is the Loxone Touch Slim Flex CO2 Tree. With Loxone Air, there is the Loxone Touch Slim Flex 24V Air.
We sell the matching frame individually: Touch Slim Flex Frame White and Touch Slim Flex Frame Anthracite.
How can you design your Touch?
- Go to the page: https://configurator.loxone.com/
- Configure your custom Touch Flex there.
- Then click the “Share” button at the top of the Configurator.
- A link will then appear.
- Paste this link into the field on this product page and you will receive your personal custom Touch Flex within 2–3 weeks.
The Touch Flex is custom-made to order and is therefore excluded from returns.
Electrical specifications
| Supply voltage | 10 … 30 V DC |
|---|---|
| Power consumption | Standby: 0.1 W, max. 0.92 W at 100 % brightness |
Interfaces
| LOXONE Air | 868 MHz (SRD band Europe), 4 channels, max. 15.1 mW e.r.p. 915 MHz (ISM band Region 2), 10 channels, max. 13.2 mW internal antenna |
|---|
Controls
| Touch area | capacitive touch detection up to 4 touch points |
|---|---|
| Click feedback | Yes |
| Backlight | Yes |
Measuring range
| Temperature | -10 … 125 °C ± 0.5 °C / -14 … 257 °F ± 0.9 °F |
|---|---|
| Humidity | 0 … 100 % RH ± 2 % (non-condensing) |
| CO2 | 400 … 5,000 ppm (± 100 ppm, ± 10 % of reading) |
Ambient conditions
| Temperature | -20 … 40 °C / -4 … 104 °F |
|---|---|
| Humidity | max. 95 % RH (non-condensing) |
| Degree of protection | IP30 |
Operating conditions of the CO2 sensor
| Temperature | 10 … 50 °C / 50 … 122 °F |
|---|---|
| Humidity | 10 … 90 % RH (non-condensing) |
| Max. dew point | 35 °C / 95 °F |
| Air pressure | 850 … 1 100 hPa |
Within the first 12 hours after switching on, the CO2 sensor calibrates itself automatically for the first time. During this time, the sensor values may be inaccurate. Over time, the CO2 sensor continues to calibrate itself, provided it is exposed to fresh air (~400 ppm CO2) at least once a week.
Terminals
| Terminal type | DG220B |
|---|---|
| Conductor cross-section | 0.28 … 0.8 mm² / AWG 23 … 18 |
| Stripping length | 5 … 6 mm / 0.2 … 0.24” |
| Temperature resistance | -40 … 105 °C / -40 … 221 °F |
Product properties
| Colour | Anthracite (RAL 9005) |
|---|---|
| Gloss level | Matt |
Weight & dimensions
| Net weight | 36 g |
|---|---|
| Gross weight | 80 g |
| Product dimensions | 104.1 x 44.5 x 18.8 mm / 4.1 x 1.75 x 0.74″ (L x W x H) |
| Package dimensions | 123 x 87 x 29 mm / 4.84 x 3.43 x 1.14″ (L x W x H) |
Product dimension drawing

Connections