Reading in two 0–10 V sensors via 1-Wire
Many sensors output their measured value as a voltage from 0 to 10 V. If no analogue inputs are free on your Loxone Miniserver or the Extensions, our adapter reads two of these sensors via the 1-Wire bus. So you only need one free spot on the 1-Wire line instead of two analogue inputs.
The adapter sits on the DIN rail in the distribution board and supplies the sensors as well: each input has 24 V, 0 V and the 0–10 V signal input, each protected with 315 mA. It generates the 5 V for the 1-Wire chips internally, so you do not need an additional supply. In Loxone Config it appears as a DS2438 in the 1-Wire search.
We supply the adapter as a kit: the small SMD components are already soldered on; you solder in the remaining components and the terminals yourself. The instruction video below shows how.
Features
- Reads two 0–10 V sensors into Loxone via 1-Wire (detected as DS2438)
- Supply: 24 V DC, with 12 V sensors it can also be operated with 12 V DC
- Supplies the sensors with 24 V DC, fuse 315 mA per input
- 2 inputs: 24 V, 0 V, 0–10 V
- Output: 1-Wire (GND + DQ), internal 5 V supply, no external 5 V supply needed
- DIN rail housing, width 2 modules (1 module = 17.5 mm)
- Spare fuses: fine-wire fuse 5 × 20 mm medium time-lag (pack of 10)
Scope of delivery
- Kit: PCB with SMD components already soldered, remaining components and terminals for soldering in, DIN rail housing (2 modules)