Features
- Fully automatic end position detection
- Standardised Hirschmann plug
- Reliable wireless coverage thanks to Loxone Air technology
- Flexibility: the 5A relays can be used freely, for example to control lighting circuits, drives, fans or pumps. Thanks to its IP54 certification, the Shading Actuator Air is the universal solution for outdoor areas
Electrical specifications
| Power supply | 110 … 230VAC, 50/60Hz |
|---|---|
| Power consumption | typ. 0.25 W, max. 0.90 W |
| Power loss at max. load | 1.2W |
| Minimum load for end position detection | 90W |
| Max. inrush current | 15 A |
| Outputs | 2 relays, each 5A@cos φ = 1 (total load max. 5A) |
Interfaces
| LOXONE Air | LOXONE Air: 868MHz (SRD band Europe), 4 channels selectable max. transmission power 15.1mW e.r.p. 915MHz (ISM Band Region 2), 10 channels selectable max. transmission power 13.2mW |
|---|
Ambient conditions
| Temperature | -30 … 50°C / -22 … 122°F |
|---|---|
| Humidity | max. 95% r.H. (non-condensing) |
Connections
| Plug connection | Hirschmann STAK 3, STAS 3 |
|---|
Wiring diagram

Product properties
| Colour | Black: RAL 9005 |
|---|---|
| Gloss level | Matt |
Weight & dimensions
| Net weight | 94g |
|---|---|
| Gross weight | 125 g |
| Product dimensions | 129.1×32.5×26.8mm / 5.08×1.28×1.06” (LxWxH) |
| Package dimensions | 186x77x30mm / 7.32×3.03×1.18” (LxWxH) |
Product dimension drawing

Certifications & standards
| Protection class | IP54 |
|---|