Features
- Easy installation thanks to Loxone Air
- High durability: reliable for more than 500,000 closing cycles
- Almost silent
- Low standby consumption
- Freely assignable button
- Integrated temperature sensor
Technical data
| Power supply | 11 … 30 VDC or 2x 1.5 V AA batteries |
|---|---|
| Power consumption | typ. 120mW, max. 3.6W |
| Power loss at max. load | 3.6W |
| Contact force | 100N (battery operation), 150N (24V operation) |
| Stroke length | 5.0mm / 0.197" |
| Measuring range temperature sensor | -40 … 125°C +/- 0.5°C -40 … 257°F +/- 0.9°F |
| Travel times | • 0% – 100%: ~20s • 100% – 0%: ~21s |
Interfaces
| LOXONE Air | 868 MHz (SRD band Europe), 4 channels, max. 15.1 mW e.r.p. 915 MHz (ISM band Region 2), 10 channels, max. 13.2 mW internal antenna |
|---|
Ambient conditions
| Temperature | -20 … 55 °C / -4 … 131 °F |
|---|---|
| Humidity | max. 80 % RH (non-condensing) |
Terminals
| Terminal type | SERIES 9176 IDC |
|---|---|
| Conductor cross-section | Ø 0.8mm (0.5mm² / AWG 20) |
Connections
| IDC technology | The wires of a cable are pressed into a single insulation displacement terminal using our IDC tool. This connection technology works without soldering, screwing or stripping. The IDC tool is included in the scope of delivery of the Miniserver, Miniserver Compact and the Tree Extension. It can be purchased separately in the shop: LOXONE IDC Tool (100226) |
|---|
Wiring diagram

Product properties
| Generation | Gen.2 |
|---|---|
| Colour | White: RAL 9003 + Black: RAL 9005 + Green: RAL 6018-P |
| Gloss level | Matt |
Weight & dimensions
| Net weight | 165 g |
|---|---|
| Gross weight | 185 g |
| Product dimensions | 45×47.5×76.5mm / 1.77×1.87×3.01” (LxWxH) with valve adapter 45×47.5x70mm / 1.77×1.87×2.76" (LxWxH) without valve adapter |
| Package dimensions | 60x83x52mm / 2.36×3.27×2.05" (LxWxH) |
Product dimension drawing

Certifications & standards
| Protection class | IP20 |
|---|

